products

Product Detail

15W Single Output Switching Power Supply         MS-15 series

Low price and high reliability
105
output capacitor
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With Short-circuit and overload protection
Compact size, light weight
100% full-load burning test
2 year warranty 

SPECIFICATIONS

OUTPUT

 

Model

MS-15-5

MS-15-12

MS-15-24

DC Voltage

5V

12V

24V

Rated Current

3A

1.3A

0.7A

Current Range

0-3A

0-1.3A

0-0.7A

Rated Power

15W

15.6W

16.8W

Ripple & Noise

50mVp-p

50mVp-p

100mVp-p

Voltage Adj. Range

10,-5%

10%

±10%

Voltage Tolerance

±2%

±1%

±1%

Inlet Stability

±0.5%

±0.5%

±0.5%

Load Stability

±1%

±0.5%

±0.5%

Setup,Rise,Hold Up Time

200s,100ms,30msat full load

 

 

INPUT

 

Voltage Range

100~240VAC 47-63Hz;240~370VDC

AC Current

0.5A/115V 0.25A/230V

Efficiency

65%

68%

72%

Inrush Current

Cold-start current 15A/115V 30A/230V

Leakage Current

<0.5mA/240VAC

 

 

PROTECTION

 

Over Load

105%~150%

Protection type:Foldback current limiting Reset: auto recovery

Over Voltage

…………

Over Temp.

…………

 

 

ENVIRONMENT

 

Working Temp., Humidity

-10~+60(Refer to output derating curve), 20%~90%RH

Storage Temp., Humidity

-20~+85,10%~95%RH

Temp. Coefficient

±0.02%/(0~50%)

Vibration

10~500Hz,2G 10min,/1cycle,Period for 60min,each axes

 

 

SAFETY

 

Withstand Voltage

I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

 

 

STANDARD

 

Safety Standard

Meet UL1012 requirement(Not apply for the mark)

EMC Standard

Meet FCC PART15 J Conduction class B

 

 

OTHERS

 

Dimension


 85*58*38mm(L*W*H)


Weight

0.2Kg

 

 

NOTE

 

1.The testing condition for the parameter above is:230VAC input,rated load,2570% RH.Humidity.

2.Error.include the setting error,line stability and load stability.

3.Wave test:adopting “A12”double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.

4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.

5.Load stability test:the load is from 0% to 100%.

Online Inquiry